INSTALLATION
1.
Position seal (Figure 2, Item 4) in thermostat housing (Figure 2, Item 5).
2.
Install thermostat (Figure 2, Item 3) in thermostat housing (Figure 2, Item 5).
3.
Coat one surface of gasket (Figure 2, Item 2) with light coat of automotive and artillery grease and position
gasket over four holes on water manifold header (Figure 2, Item 1).
4.
Aligning holes in thermostat housing (Figure 2, Item 5) and header (Figure 2, Item 1), install housing with four
screw assembled lockwashers (Figure 2, Item 11).
5.
Connect radiator bypass hose (Figure 2, Item 10) to thermostat housing (Figure 2, Item 5) and bypass tube
(Figure 2, Item 8) and tighten two clamps (Figure 2, Item 9).
6.
Connect radiator inlet hose (Figure 2, Item 7) to thermostat housing (Figure 2, Item 5) and tighten clamp
(Figure
2, Item 6).