INSTALLATION
NOTE
Male pipe threads must be wrapped with antiseize tape before installation.
1.
Install actuator (Figure 2, Item 4) on water manifold (Figure 2, Item 1).
2.
Install adapter (Figure 2, Item 5) on actuator (Figure 2, Item 4).
3.
Connect actuator-to-fan hose (Figure 2, Item 6) on adapter (Figure 2, Item 5).
4.
Install adapter (Figure 2, Item 3) in actuator (Figure 2, Item 4).
5.
Connect air hose (Figure 2, Item 2) to adapter (Figure 2, Item 3).
TM 9-2320-272-23-3
0447
0447-4