INSTALLATION
CAUTION
•
Ensure no particles of plugging become trapped in crane hydraulic system during
installation of hosing or tubes. Failure to comply may result in damage to equipment.
•
Ensure plug is removed from lift cylinder fitting before installation.
NOTE
•
Do not twist hose or attempt to install hose with one wrench.
•
Hose fitting ends connected by a single hexagonal nut cannot be installed until the
hexagonal nut end is connected at the opposite end. The entire hose must be free to turn
whenever installing hose connected by a single hexagonal nut.
1.
Remove plug (Figure 2, Item 4) from lift cylinder fitting (Figure 2, Item 3) and install snubber valve
(Figure
2,
Item
2).
2.
Connect hose (Figure 2, Item 1) to snubber valve (Figure 2, Item 2).
TM 9-2320-272-23-4
0706
0706-4