REMOVAL
1.
Remove screw (Figure 1, Item 8), lockwasher (Figure 1, Item 7), and lever (Figure 1, Item 6) from switch
(Figure
1,
Item
11). Discard lockwasher.
2.
Remove nut (Figure 1, Item 5), lockwasher (Figure 1, Item 4), identification plate (Figure 1, Item 3), and switch
(Figure 1, Item 11) from bracket (Figure 1, Item 9). Discard lockwasher.
3.
Disconnect two leads (Figure 1, Item 12) from switch (Figure 1, Item 11).
4.
Remove two locknuts (Figure 1, Item 2), screws (Figure 1, Item 10), and bracket (Figure 1, Item 9) from
instrument panel (Figure 1, Item 1). Discard locknuts.
TM 9-2320-272-23-5
0800
0800-2