CHEMICAL AGENT ALARM WIRING HARNESS REMOVAL
NOTE
The cable is provided in two sections. A short wire harness with a screw-on receptacle
completes the circuit for the detector and alarm units to the main power source. This harness
is only supplied when both chemical detector and alarm units are issued to the field.
1.
Remove nut (Figure 1, Item 4) and receptacle (Figure 1, Item 1) from detector bracket (Figure 1, Item 3).
2.
Remove screw (Figure 1, Item 6), clamp (Figure 1, Item 7), and cable (Figure 1, Item 2) from locations A, B,
C, D, E, and F along left side fender (Figure 1, Item 5) and underside of vehicle.
3.
Remove six clamps (Figure 1, Item 7) from cable (Figure 1, Item 2).
TM 9-2320-272-23-5
0774
0774-2