TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BATTERY SYSTEM
2. BATTERlES ARE HOT, ELECTROLYTE IS BOILING, OR EXCESSIVE USE OF WATER
NOTE
If STE/ICE is available, perform NG50 - Charging Circuit Tests
(para. 2-24).
Check electrolyte temperature and specific gravity and note reading (TM 9-6140-200-14).
a.
If temperature is over 120°F (49°C) and specific gravity is 1.280 or greater, batteries
are being overcharged. Go to generating system troubleshooting (malfunction 9,
test 1).
b.
If battery temperature is over 120°F (49°C), but specific gravity is 1.236-1.260,
recharge batteries (TM 9-6 140-200-14).
END OF TESTING!
2-97


Back to Top