TM 9-2320-272-24-1
3-202. PRIMARY AIR RESERVOIR (SUPPLY TANK) REPLACEMENT (Contd)
b. Installation
NOTE
l
If installing new reservoir, use old reservoir fittings.
l
Wrap all male pipe threads with antiseize tape before
installation.
1.
Install reservoir (5) on two clamps (14) with clamps (12), screws (11), and new locknuts (13).
2.
Install two screws (11) and new locknuts (13) on clamps (12).
3.
Connect treadle valve supply line (3) to adapter (4).
4.
Connect supply line (2) to adapter (4).
5.
Connect primary relay valve supply line (1) to elbow (10).
6.
Connect drain line (8) to elbow (9).
7.
Connect wet reservoir supply line (6) to elbow (7).
3-564