Table 16. Circuit Breakers and Glove Compartment Door - Continued.
Key
Control/Indicator
Function
3.
Circuit Breaker
Buttons
WARNING
Do not attempt to check and reset circuit breakers
while driving the tractor. Always pull safely to side
of road first. If tractor cannot be safely operated due
to a circuit breaker that cannot be reset, do not
attempt to operate tractor. Failure to comply may
result in damage to equipment or possible injury or
death to personnel. Seek medical attention in the
event of an injury.
There are nine 20 amp circuit breakers on the access
panel. If an electrical component will not function or
ceases to function (for example, the heater fan stops
with FAN switch in HIGH position), the circuit
breaker may have tripped and should be checked and
reset. To reset any circuit breaker, open panel cover,
identify circuit breaker by its number or if button is
out, and depress the button. If button remains in after
depressing it and component becomes operational,
close panel cover. If circuit breaker trips again, an
overload or short in the circuit has taken place. If
tractor can be safely operated without the affected
electrical item, complete mission and notify Field
Maintenance. If tractor cannot be safely operated,
secure tractor and notify Field Maintenance.