AIR SYSTEM AND BRAKES - CONTINUED
MALFUNCTION
Trailer air supply control is not pushed in (ON).
CORRECTIVE ACTION
Check trailer air supply control is pushed in (charging position). Push in air
supply control (WP 0005).
MALFUNCTION
Inter-vehicular air hoses are not securely connected between tractor and trailer.
CORRECTIVE ACTION
Check both inter-vehicular air hoses are connected securely between tractor
and trailer (WP 0012). Connect hoses securely (WP 0012).
MALFUNCTION
Leaks in air system.
CORRECTIVE ACTION
Check for obvious leaks in tractor air system. If any leaks are found, notify
supervisor. If no leaks are found, notify supervisor to troubleshoot trailer.
END OF TASK
DRIVELINE AIR CONTROL SYSTEM
SYMPTOM
Driveline will not disengage (indicator lamp stays on) when differential
LOCK/UNLOCK is moved to UNLOCK position.
MALFUNCTION
Driveline has not had enough time to disengage since activated or excessive
driveline wind up has occurred.
CORRECTIVE ACTION
1. Check system has been unlocked long enough for system to disengage.
Put LOCK/UNLOCK control in UNLOCK position and wait for lamp to
go off (WP 0005).
2. If LOCK indicator lamp stays on, excessive driveline wind up may have
occurred. Back up slowly and check if LOCK indicator lamp goes off. If
indicator lamp stays on, notify supervisor.
END OF TASK
TM 9-2320-273-10
0023
0023-11