ELECTRICAL SYSTEM
SYMPTOM
One or more electrical systems not working.
MALFUNCTION
Switch(es) are not in the ON position or inter-vehicular cable is not securely
connected.
CORRECTIVE ACTION
Check appropriate switch(es) are in ON position and, if a lamp system, that
blackout switch is in NORMAL position. If tractor is coupled to trailer and
problem is with trailer lamp system, ensure inter-vehicular cable is
connected securely between tractor and trailer. Turn appropriate switch(es) in
ON position. If necessary, securely connect inter-vehicular cable.
MALFUNCTION
Resettable circuit breakers have tripped (M915A1).
CORRECTIVE ACTION
NOTE
M915A1 is equipped with resettable circuit breakers.
1. Check resettable circuit breakers have not popped out, indicating a
momentary overload or short circuit. Open access panel and push in to
reset any circuit breakers which have popped out.
2. Recheck failing electrical system. If resetting fails to correct problem or
breaker button pops out again, notify supervisor.
END OF TASK
STEERING
SYMPTOM
Hard steering, shimmy, or wandering.
MALFUNCTION
Incorrect tire air pressure.
CORRECTIVE ACTION
Check cold air pressure in all tires. Fill as required. Refer to Tire Pressure in
WP 0003 for proper pressures.
TM 9-2320-273-10
0023
0023-14