Troubleshooting Malfunctions (Cont)
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
5. AUXILIARY PUMP WILL NOT PUMP FUEL (CONT).
Step 6. Check for defective auxiliary pump power wire. Remove auxiliary pump junction box cover
(para 7-48). Check resistance of red wire between relay terminal E3 and APC AUXILIARY
PUMP CONTROL switch.
If resistance is more than zero ohms, replace wire, install main, control, and
auxiliary pump junction box covers (paras 7-47, 7-48, and 7-49).
Step 7. Check for defective auxiliary pump relay ground wire. Disconnect blue wire from auxiliary
pump junction box and relay terminal A5. Check resistance of blue wire.
If resistance is more than zero ohms, replace wire, install main, control, and
auxiliary pump junction box covers (paras 7-47, 7-48, and 7-49).
Step 8. Connect batteries (para 7-91). Check for defective auxiliary pump relay. Set APC
AUXILIARY PUMP CONTROL switch to ON.
If AUXILIARY PUMP does not run, replace auxiliary pump relay (para 7-48),
install main and control junction box covers (paras 7-47 and 7-49).
2-233