Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
8. PRIMARY PUMP MAKES EXCESSIVE NOISE.
Step 1. Check that primary pump and motor mounting hardware is tight and not damaged.
Tighten loose mounting hardware and replace damaged parts (paras 25-5
and 25-6).
Step 2. Remove inspection cover from primary pump. Check to see that pump motor coupling is not
loose or damaged.
Tighten loose coupling or replace damaged parts (para 25-5 and 25-6).
2-239