o
TM 9-2320-279 -20-1
Troubleshooting Malfunctions (Cent)
Table 2-9. TrouMeshoofing (Cent)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
11. TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL (CONT).
ORANGE AND
FOUR
WHITE WIRES
Step
9.
Check for defective TLI TANK LEVEL INDICA~R gage to terminal board wiring.
Disconnect orange and white wires from TLI TANK LEVEL INDICA~R gage and control
junction box terminal board. Check resistance of each wire.
If resistance is more than zero ohms in either wire, replace defective wire, install
TLI TANK LEVEL INDICATOR gage cover and control junction box cover
(para 7-49).
2-245