TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cent)
12-15. TROUBLESHOOTING INSTRUCTIONS (CONTI. I
Table 2-9. Troubleshooting (Cent)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
11.
TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL (CONT).
YELLOW
WIRE
Step 10. Check for defective TLI TANK LEVEL INDICATOR switch wire to terminal board.
Disconnect connector. Check resistance of yellow wire from connector to terminal board.
If resistance is more than zero ohms, replace defective TLI TANK LEVEL
INDICA~R switch wire, install main and control junction box covers (paras 7-47
and 7-49).
Step 11. Check for defective TLI TANK LEVEL INDICATOR ground wire. Check resistance of blue
wire from terminal board to ground point.
If resistance is more than zero ohms, replace wire.
2-246