Troubleshooting Malfunctions (Cent)
]
2-15. TROUBLESHOOTING INSTRUCTIONS (CONT). ]
Table 2-9. Troubleshooting (Cent)
Malfunction
Test or Inspection
Corrective Action
110
TANKER SYSTEM (CONT)
TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL (CONT).
NOTE
From this point on, the tests for Model A (plastic sensor) and Model B (brass sensor)
are different. Do steps 13 through 16 for Model A and steps 17 and 18 for Model B.
\\
FEMALE
MALE
n-,.
PIN
SOCKET
PHOTOTRANSISTOR
CONNECTOR
RED WIRE
Y’
Step 13. Connect batteries (para 7-91). Check for
FEMALE
PIN
TA187425
defective TLI TANK LEVEL INDICATOR adjuster.
Disconnect red wire connector. Disconnect phototransistor connector (male socket and
female pin). Set TLI TANK LEVEL INDICATOR switch to ON. Check for 1.2 to 8.Ovdc on
each female pin, using red wire as ground.
If voltage is lower than 1.2vdc or higher than 8 .Ovdc, replace tank level indicator
adjuster (para 7-87) and install main junction box cover (para 7-47).