TM 9-2320-279 -20-1
Troubleshooting Malfunctions (Cent)
~ 2-15.
TROUBLESHOOTING INSTRUCTIONS (CONT]. I
Table 2-9. Troubleshooting (Cent)
Vlalfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
I 1. TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL (CONT).
FUSE
‘2–W
FUSED
LEAD
_
Lm
Glj
TA1 87420
NOTE
From this point on, do not install junction box covers, gage covers, or operate tanker
until problem is solved and this manual says to do so. Refer to FO- 1, sheets 3 and 4
for M978 Electric Diagram.
Step 6. Remove control junction box cover (para 7-49). Disconnect fuse holder and look for blown
fuse.
Replace blown fuse.
Step 7. Remove fused lead from TLI TANK LEVEL INDICA~R and APC AUXILIARY PUMP
CONTROL switches. Check wire resistance.
If resistance is more than zero ohms between fuse holder and wire terminals,
replace fused lead.
Step 8. Check for defective TLI TANK LEVEL INDICATY)R switch. Disconnect connectors. Check
switch resistance when TLI TANK LEVEL INDICA’IT3R switch is in the ON position.
If resistance is more than zero ohms, replace defective TLI TANK LEVEL
INDICA’IOR switch (para 7-49), install TLI TANK LEVEL INDICATOR gage cover
(para 7-86).
2-244