TM 9-2320-279-20-1
.
Troubleshooting Malfunctions (Cent)
Table 2-9.
Troubleshooting (Cent)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT
2. COOIANT PUMP FAILS TO OPERATE (INDICATOR LIGHT COMES ON).
4
-a
.
4
TA500405
Step 1. Check coolant pump for loose electrical connections.
Tighten loose connections.
Step 2. Check voltage at coolant pump. Place positive (+) probe at terminal No. 4. Place negative (-) probe
on known good ground.
If 24 vdc is present, go to Step 3.
If 24 vdc is not present, repair or replace wire No. 1530 (para 20-2).
Step 3. Perform continuity check on ground wire No. 1317 of coolant pump.
If continuity is present, repair or replace coolant pump (para 20-2).
If continuity is not present, repair or replace wire No. 1317.
Step 4. If problem has not been solved, notify the supervisor.
Change 2
2-253