TM-9-2320-279-20-1

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; ORGANIZATIONAL MAINTENANCE, VOLUME 1 OF 3

  TM-9-2320-279-20-1 - Page 343 of 985

TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
2-15. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 2-9. Troubleshooting
(Cont)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
11. TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL (CONT).
MALE
SOCKET
FEMALE
PIN
NOTE
There are two models of fuel level sensor. Model B is shown.
Do step (17) for Model B only.
Step 17.
Check for defective fuel level sensor. Disconnect two connectors (female pin and male
socket). Connect one probe from meter to black wire. Raise all four float switches and hold
in up position. Check resistance on red, yellow, blue, and brown wires.
If resistance is more than zero ohms on any wire, replace fuel level sensor
(para 7-88).
Step 18.
If TLI TANK LEVEL INDICATOR gage does not register, replace tank level indicator
adjuster (para 7-87).
2-250