Troubleshooting Malfunctions (Cent)
Table 2-9. Troubleshooting (Con#j
●
●
o
●
●
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
11. TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL (CONT).
MALE
SOCKET
PHOTOT
CON
Step 14. Disconnect phototransistor connector. Set TLI TANK LEVEL INDICA~R switch to ON.
Ground each female pin of phototransistor connector (male socket and female pin). Check
that TLI TANK LEVEL INDICATOR gage drops from FULL to approximately 3/4.
If TLI TANK LEVEL INDICA~R gage does not drop from FULL to approximately
3/4, replace tank level indicator adjuster (para 7-87) and install main junction box
cover (para 7-47).
Step 15. Disconnect LED connector (female pin and male socket). Set TLI TANK LEVEL
INDICA’IOR switch to ON. Check for 24 to 28vdc at each female pin.
If voltage is less than 24vdc, replace tank level indicator adjuster (para 7-87).
Step 16. If TLI TANK LEVEL INDICATUR gage does not register, repIace fuel level sensor
(para 7-88).
2-249