TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cent)
2-13. TROUBLESHOOTING INSTRUCTIONS (CONT).
I
Table 2-9.
Troubleshooting (Cent)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT (CONT)
3. HEAT OUTPUT TO BAITERY BOX TOO LOW.
h
.
‘-
EXHAUST~
PIPE
BAITERY
BOX
WATER
EXtiAUST
PIPE
T&50049a
Step L Check exhaust pipe connections at water jacket and battery box.
Tighten loose connections.
Step 2. Check exhaust pipe for kinks or damage.
Repair or replace e@aust pipe (para 20-2).
Step 3. If problem has not been solved, notify the supervisor.
2-254