TM 9-2320-279 -20-1
Troubleshooting Malfunctions (Cent)
Table 2-9. Troubleshooting (Cent)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT
1.
COOIANT PUMP FAILS TO OPERATE (INDICATOR LIGHT DOES NOT COME ON).
h
.
*
.
WIRE
NO. 1082
SWITCH
1
TA500537
Step 1. Remove heater compartment cover (para 20-2). Check for loose electrical connections at
coolant pump sw”tch and circuit breaker connections.
Tighten loose connections.
Step 2. Check for defective circuit breaker No. 4 (fig. 2-2), Test voltage across circuit
breaker No. 4.
If 24 vdc is present, go to Step 3.
If 24 vdc is not present, replace circuit breaker No. 4 (para 7-43)
Step 3. Check for voltage at terminal No. 1 of coolant pump switch. Place positive (+) probe on terminal
No. 1. Place negative (-) probe on known good ground.
If 24 vdc is present, go to Step 4.
If 24 vdc is not present, repair or replace wire No. 1082.
Step 4. Check for voltage at terminal No. 2 of coolant pump switch. With switch in ON position, place
positive (+) probe on terminal No. 2. Place negative (-) probe on known good ground.
If 24 vdc is present, go to Step 5.
If there is no voltage, replace coolant pump switch (para 20-2).
Step 5. If problem has not been solved, noti~ the supervisor.
Change
2
2-251