TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
WARNING
Adhesives, solvents, and sealing compounds can
burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or
death, keep away from open fire and use in
well-ventilated area. If adhesive, solvent, or
sealing compound gets on skin or clothing, wash
immediately with soap and water.
(7)
(8)
(9)
Apply pipe thread sealing compound to
threads of two adapters (13 and 14).
Thread wire (15) injunction box (4) and
install adapter (13), adapter (14), and
nut (16).
Install relay (17) and wire (18) in junction
box (4) with two screws (19),
lockwashers (20), and nuts (21).
7-155