TM-9-2320-279-20-1

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; ORGANIZATIONAL MAINTENANCE, VOLUME 1 OF 3

  TM-9-2320-279-20-1 - Page 731 of 985

TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-49. CONTROL JUNCTION BOX REMOVAL/INSTALLATION (M978) (CONT).
NOTE
Matchmark elbows.
(19)
Remove two elbows (48)
from control junction
box (13).
(20)
Remove two plugs (49) and
adapters (32 and 27).
b. Installation.
WARNIN G
Adhesives, solvents, and
sealing compounds can burn
easily, can give off harmful
vapors, and are harmful to
skin and clothing. To avoid
injury or death, keep away
from open fire and use in
well-ventilated area. If
adhesive, solvent, or sealing
compound gets on skin or
clothing, wash immediately
with soap and water.
(1)
Apply pipe thread sealing
compound to threads of two elbows (1), plugs (2), and adapters (3 and 4).
(2) Install two elbows (1), plugs (2), and adapters (3 and 4) in control junction box (5).
7-162


Back to Top