TM-9-2320-279-20-1

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; ORGANIZATIONAL MAINTENANCE, VOLUME 1 OF 3

  TM-9-2320-279-20-1 - Page 735 of 985

TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-49. CONTROL JUNCTION BOX REMOVAL/INSTALLATION (M978) (CONT).
(19)
Connect three connectors (43).
(20)
Install three wires (44) on contact
button (38) with two screws (45).
NOTE
Replace plastic cable ties as necessary.
(21)
Install two wires (23 and 25),
fuseholder (46), two lockwashers (47),
and nuts (48) on rotary switch (31).
(22)
Install fuse (49) in fuseholder (46) and
connect.
c. Follow-on Maintenance.
(1)
Install TLI TANK LEVEL INDICATOR
(para 7-87).
(2) Install SP SAMPLING PROBE valve
bracket (para 23-35).
(3)
Connect batteries (para 7-91).
(4)
Check operation of control functions
(TM 9-2320-279-10).
END OF TASK
Section VII.
MISCELLANEOUS SWITCHES
7-50. TURN SIGNAL SWITCH REMOVAL/INSTALLATION.
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
INITIAL SETUP
Models
Personnel Required
All
MOS 63S, Heavy wheel vehicle mechanic
Test Equipment
References
None
None
Special Tools
Equipment Condition
None
TM or Para
Condition Description
Supplies
Para 7-19
Instrument panel removed.
Connector, electrical, butt, Item 19,
Appendix C
Special Environmental Conditions
Tags, identification, Item 48, Appendix C
None
Ties, cable, plastic, Item 52, Appendix C
General Safety Instructions
None
7-166


Back to Top