TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-82. HOUR METER OIL PRESSURE SWITCH REMOVAL/INSTALLATION (CONT).
a. Removal.
NOTE
Tag and mark wires before removing.
(1)
Remove two screws (1) and wires (2)
from oil pressure switch (3).
(2)
Remove oil pressure switch (3) from
manifold (4).
b. Installation.
WARNIN G
Adhesives, solvents, and sealing compunds
can burn easily, can give off harmful
vapors, and are harmful to skin and
clothing. To avoid injury or death, keep
away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(1)
Coat threads of oil pressure switch (3)
with pipe thread sealing compound, and
install oil pressure switch in
manifold (4).
(2)
Connect two wires (2) to oil pressure
switch (3) with two screws (1).
c. Follow-on Maintenance.
(1)
Connect batteries (para 7-91).
(2)
Check operation of hour meter
(TM 9-2320-279-10).
(3)
Install engine side panel (TM 9-2320-279-10).
(4)
Close engine cover (TM 9-2320-279-10).
END OF TASK
7-297