TM 9-2320-279-34- 1
Electrical System Maintenance Instructions (Cont)
6-12. CRANE OVERLOAD SENSOR SWITCHES REMOVAL/INSTALLATION (M977, M985 )
(CONT).
(3)
(4)
Figure 6-1. Main Overload Switch Wiring.
Tighten nut (6) and jamnut (7) until one screw
thread is below surface of nut (6).
Adjust nut (8) and jamnut (9) until main
overload switch (1) is 1/4 in. (6 mm) from switch
sensing plate (10),
c. Reduced Overload Switch Remova l
(M977 only) .
NOT E
Tag and mark wires before removal.
(1)
Disconnect three wires (1) at
connectors (2).
NOT E
Remove clips and plastic cable ties.
(2)
Remove nut (3) and overload switch (4)
from mounting bracket (5).
6-66