TM 9-2320-279-34- 1
Electrical System Maintenance Instructions (Cent)
6-12. CRANE OVERLOAD SENSOR SWITCHES REMOVAL/INSTALLATION (M977, M985 )
.
(3)
(4)
Tighten nut (6) and jamnut (7) until one screw
thread is below surface of nut (6).
Adjust nut (8) and jamnut (9) until reduced
overload switch (1) is 1/4 in. (6 mm) from switch
sensing plate (10).
NOT E
Remove clips and plastic cable
ties.
(2)
Remove four screws (3) and
mounting clamp (4) from
mast (5).
(3)
Remove mast overload
switch (6) from mounting
clamp (4).
e. Mast Overload Switc h
Removal (M977 only) .
NOT E
Tag and mark wires before
removal.
(1)
Disconnect three wires (1)
at connectors (2).
6-68