TM 9-2320-280-20-1
STARTER MOTOR VOLTAGE TEST #68
Description:
This procedure measures the voltage
present at the starter motor positive
terminal, in the 0-32 volts range.
Test requires DCA hookup only.
Typical Applications:
Check Starter Motor Voltage
Test Procedure:
1. Disconnect Fuel Solenoid wire 54A to prevent
starting.
2. Set TEST SELECT switch to 68.
3. Press and release TEST button.
4. Crank the engine and observe the displayed
Votage.
Pm-Test Procedures:
Run Confidence Test.
Control Functions:
01,02,03,04,06
Possible Error Messages:
none