TM-9-2320-280-20-1

TRUCK, UTILITY: M998 SERIES

TECHNICAL MANUAL; UNIT MAINTENANCE; VOLUME 1 OF 3

JANUARY 1996

  TM-9-2320-280-20-1 - Page 847 of 888

TM 9-2320-280-20-1
DC VOLTAGE O TO 45 VOLTS TEST #89
Description:
This procedure measures voltage in the range of
-45 to 45 volts. The VTM is used as a DC voltmeter
with the decimal point in the correct position. This
test must be done with the component being tested
turned on. Test requires the use of the TK adapters
and transducers
Typical Applications:
Fuel Solenoid
Starter Solenoid
Alternator Output
Any DC Voltage measurement
Test Procedure:
1. Connect test probe cable W2. Attach P1 to J4.
2. Connect the desired test leads to P2.
3. Set TEST SELECT switch to 89.
4. Short leads together. Press and hold TEST
button until CAL appears on display.
5. Release TEST button and wait for offset value to
appear on display.
6. If offset is within -6.8 to 6.8 proceed. If not, go to
DCA Troubleshooting Procedure.
7. Press and release TEST button. Observe
displayed value.
Pre-Test Procedures
Run Confidence Test.
Control Functions:
01,02,03,04,06
Possible Error Messages
E005 Offset not performed.
2-750