When applying and removing MIL-PRF-680 Type II or IV degreasing solvent, personnel shall wear
chemical-resistant gloves and a face shield or goggles to prevent skin and eye contact with solvent and oil,
grease, and other contaminants removed with solvent. In case of skin contact, remove any contaminated
clothing before reuse. In the event of eye contact, flush eyes with large amounts of water for at least 15
minutes or until irritation subsides. Do not have food or drink in the vicinity. Failure to comply may result in
injury to personnel. Seek medical attention in the event of an injury.
Ensure all nuts on all air tube fittings are properly tightened during installation. Failure to comply may result
in damage to equipment or possible injury to personnel. Seek medical attention in the event of an
injury.Improper cleaning methods and use of unauthorized cleaning solvents may result in damage to
equipment or possible injury to personnel. Seek medical attention in the event of an injury.
Compressed air source shall not exceed 30 psi (207 kPa). When cleaning with compressed air, eye shields
must be worn. Failure to comply may result in injury to personnel. Seek medical attention in the event of an
injury.
Spring brake chambers contain a loaded compression spring and must be handled with extreme care. Be
careful not to drop the spring brake chamber, and always work from the side of the unit and not from the
front or back. During removal and installation, do not use an impact wrench on the release tool or strike any
part of the unit for any reason. Do not attempt to dismantle the spring brake chamber, and replace the entire
unit if any structural damage is evident. Failure to comply may result in damage to equipment or possible
injury or death to personnel. Seek medical attention in the event of an injury.
Ensure harness leads are routed to the correct wheel as labeled with white bands denoting LF, RF, LR, and
RR. Failure to comply may result in damage to equipment or possible injury or death to personnel. Seek
medical attention in the event of an injury.
MIL-PRF-680 solvent is combustible; DO NOT use or store near heat, sparks, flame, or other ignition
sources. Use mechanical ventilation whenever product is used in a confined space, heated above
temperatures, or agitated. Keep container sealed when not in use.
Contact with MIL-PRF-680 may cause skin irritation. Use chemical gloves. In case of skin contact, remove
any contaminated clothing and wash skin thoroughly with soap and water. Wash contaminated clothing before
reuse. Eye contact may cause irritation, tearing, or blurring of vision. Use face shield or goggles when eye
contact may occur. In case of eye contact, flush eyes with large amounts of water for at least 15 minutes or
until irritation subsides. Inhalation may cause irritation to upper respiratory passages. DO NOT have food or
drink in the vicinity. Failure to comply may result in death or injury to personnel. Seek medical attention in
the event of an injury.
Leaking or spilled oil may cause a slip and fall hazard. Clean any leaking or spilled oil immediately, using
suitable fluid absorbent materials. Dispose of contaminated cloths, rags, or cleaning materials in accordance
with local procedures and plans. Failure to comply may result in injury to personnel. Seek medical attention
in the event of an injury.