TM 9-2320-283-20-1
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
57 ONE STOPLAMP NOT WORKING (Continued).
1
Disconnect turn signal
switch connector, and
go to step 2.
2
Connect jumper across
circuit 25D-RD to
gray-black circuit, and
go to step 3.
3
Check for voltage at
12-volts dc
Connect circuit
Replace turn
circuit 36C-DG terminal
nominal
36C-DG to
signal switch
of connector
25D-RD, and go
(para 3-80).
to step 4.
2-175