TM 9-2320-283-20-1
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
58 BOTH REVERSE LAMPS NOT WORKING.
1
Remove circuit breaker
bracket far enough to
access circuit breaker
CB-3 (para 3-114), and
go to step 2
NOTE
Ignition switch must be on, battery power connected,
transmission shift control lever in reverse (R), and
blackout toggle switch in NORMAL position when doing
the following checks.
2
Check for voltage at
12-volts dc
Go to step 3
Reset circuit
circuit 38-LG terminal
nominal
breaker CB-3
of circuit breaker
and/or trouble-
CB-3
shoot CB-3 cir-
cuit.
(Refer
to malfunction
33).
3
Disconnect circuit
38-LG from 38A-LG at
connector, and go to
step 4.
4
Check for voltage at
12-volts dc
Go to step 5
Repair circuit
circuit 38-LG terminal
nominal
38-LG (para
of connector
3-127).
Install
circuit breaker
bracket (para
3-114).
5
Connect jumper wire
from circuit 38-LG to
38A-LG, and go to step
6.
6
Access reverse switch,
and disconnect circuit
38A-LG from switch
(para 3-106).
2-178