TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
76.
ONE 24-VOLT TRAILER STOPLAMP NOT WORKING (Continued).
8
Remove relay RY-2
(para 3-112), and go
to step 9.
9
Check for voltage at
12-volts dc
Go to step 10
Repair circuit
circuit 99Z-BK ter-
nominal
99Z-BK (para
minal of relay con-
3-127)
Install
nector
relays RY-2 and
RY-3, relay
connector, and
circuit breaker
bracket (para
3-112 and
3-114).
10
Check for voltage at
12-volts dc
Go to step 11
Repair circuit
circuit 99Y-BK ter-
nominal
99Y-BK (para
minal of relay con-
3-127) Install
nector
relays RY-2 and
RY-3, relay
connector, and
circuit breaker
bracket (para
3-112 and
3-114).
11
Check for voltage at
24-volts dc
Go to step 12
Reset circuit
circuit 18A-TN ter-
nominal
breaker CB-8
minal of circuit
and/or trouble-
breaker CB-8
shoot CB-8
circuit (Refer
to malfunction
35).
2-222