TM 9-2320-283-20-2
ELECTRICAL SYSTEM.
3-115.
STARTER RELAY REPLACEMENT (Continued).
LOCATION/ITEM
ACTION
REMARKS
A.
REMOVAL.
1.
Three screws (1).
Loosen.
2.
Panel (2).
Open.
3.
Two nuts (9),
Remove from item (14).
Tag wires for identifi-
lockwashers (10),
cation.
wire (11), and
wire (5).
4.
Two nuts (8),
Remove from item (14).
Tag wires for identifi-
lockwashers (7),
cation.
wire (12), and
two wires (6).
5.
Two screws (13)
Remove from item (14) and
and nuts (3).
item (4).
6.
Relay (14).
Remove.
B.
INSTALLATION.
7.
Relay (14).
Put in place on item (4).
8.
Two screws (13)
Secure two items (14) to
and nuts (3).
item (4).
9.
Two nuts (8) and
Secure two items (6) and
Two items (6) go on
lockwashers (7).
item (12) to item (14).
right side.
10. Two nuts (9) and
Secure item (11) and item (5)
Item (11) goes on top.
lockwashers (10).
to item (14).
11. Panel (2).
Close.
12. Three screws (1).
Tighten.
NOTE
Follow-on maintenance action required:
Connect battery power (para 3-120).
3-668