TM 9-2320-283-20-2
ELECTRICAL SYSTEM.
3-119.
BATTERY CHARGING (Continued).
LOCATION/ITEM
ACTION
REMARKS
A.
CONNECT CHARGER (Continued).
WARNING
Be sure charger is off before connecting
clamps
to
battery,
otherwise sparks may result, causing an explosion.
Failure to
follow this precaution may result in serious injury to you and other
personnel.
CAUTION
Turn off charger if battery feels hot (125°F) or begins gassing and
spewing electrolyte.
Damage to batteries will occur if either of
these conditions persist for a length of time.
NOTE
Battery does not need charging when battery test indicator shows
green or light
yellow
condition.
If
light yellow condition exists,
replace battery (para 3-121).
7.
Two clamps (9).
Install between two items (3)
Positive item (9)
and (10).
connects to positive
item (5) and negative
item (9) connects to
negative item (5).
B.
CHARGE BATTERY.
I
NOTE
*Shake or tilt battery at hourly intervals to mix electrolyte and to
self indicator is green.
*Stop charging when indicator is green.
8.
Battery (8).
Charge.
Refer to the battery
charging rates on page
3-690.
3-688