TM 9-2320-283-20-2
ELECTRICAL SYSTEM.
3-124. BATTERY CABLE REPLACEMENT (Continued).
LOCATION/ITEM
ACTION
REMARKS
E. POSITIVE BATTERY POWER CABLE (BATTERY-TO-RECEPTACLE) REPLACEMENT (Continued).
34 Cable (14)
a.
Line up with hole in
item (15).
b.
Secure with item (12)
and (13).
c.
Lubricate with grease.
35. Cable (14)
a.
Position on item (17).
b.
Secure with item (21).
c.
Lubricate with grease.
36. Battery ground
Connect to batteries
Refer to paragraph
cables
3-120.
F. NEGATIVE BATTERY POWER CABLE (BATTERY-TO-RECEPTACLE) REPLACEMENT.
37. Battery ground
Disconnect from batteries
Refer to paragraph
cables
3-120.
38. Screw (12), washer
Remove from item (15)
Access item (12) through
(13), and cable
hole in bottom of item
(16)
(18).
39. Cable (16)
a.
Line up with hole in item
(15).
b.
Secure with item (12) and
(13).
c.
Lubricate with grease.
40. Battery ground
Connect to batteries
Refer to paragraph
cables
3-120.
3-726