TM 9-2320-283-34-1
ELECTRICAL SYSTEM.
3-21.
ALTERNATOR AND RECTIFIER REPAIR (Continued).
LOCATION/ITEM
ACTION
REMARKS
C.
TESTING (Continued).
19.1
Trio (4)
a. Connect negative test lead
(B) of ohmmeter to output
lead (C) on item (4).
b. Touch positive lead (A) to
all three terminals (D),
(E), and (F) on item (4),
one at a time, a low
resistance should be
indicated, if not, replace
item (4).
c. Reverse ohmmeter test
leads so positive lead
(A) is connected to output
lead (C) on item (4).
d. Touch negative test lead
(B) to all three terminals
(D), (E), and (F) on item
(4), one at a time, a high
resistance should be
indicated, if not, replace
item (4).
3-124