TM 9-2320-328-13&P-1
0105-11
DRAFT
0105
Change 1
.
HWT1154
.
Step 13.
Check for 22 to 28 VDC between cab roof lightbar cable assembly wire 1626 (red) at
cab roof lightbar flasher unit, terminal 8 and a known good ground.
.
If 22 to 28 VDC are not present, repair wire 1626 in cab roof lightbar cable
assembly if repairable (TM 9-2320-325-14&P), or replace cab roof lightbar
cable assembly (WP 0291).
.
Step 14.
Put EMERG MASTER and ROOF EMERGENCY LIGHTS switches to off position
(WP 0004).
Turn Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect
switch to off position (WP 0007).
Check for continuity across ground wire (white) from
cab roof lightbar flasher unit, terminal 11 to a known good ground.
.
If there is continuity, replace cab roof lightbar flasher unit (WP 0287).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION