TM 9-2320-328-13&P-1
0105-9
DRAFT
0105
Change 1
.
HWT1152
.
Step 11.
Put EMERG MASTER switch to off position (WP 0004).
Turn Service Drive Lights Off
(TM 9-2320-422-10).
Pull battery disconnect switch to off position (WP 0007).
Check
for continuity across ROOF EMERGENCY LIGHTS switch, from terminal 5 to terminal
6, when switch is in on position.
.
a.
If there is no continuity, replace ROOF EMERGENCY LIGHTS switch
(WP 0199).
.
b.
If there is continuity, go to Step 13.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION