END OF TASK
HWT1159
WARNING
ICON 15
Ensure PTO area is clear of personnel and obstructions before engaging PUMP
PTO switch.
Failure to comply may result in injury or death to personnel and/or
damage to equipment.
NOTE
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
Step 3.
Start engine (TM 9-2320-422-10).
Set up system to pump from onboard water
tank (WP 0019). Turn on foam system (WP 0024). When discharging from NO.1
DRIVER SIDE DISCHARGE or NO. 2 PASSENGER SIDE DISCHARGE, press FLOW
button on valve control. Record GPM rate, using settings from manual metering control
valve data plate set manual metering valve to match discharge rate of flow.
Operate
bumper turret (WP 0027), under truck nozzles (WP 0028), or side discharge. Check if
foam is delivered when system is operated.
a.
If foam is delivered, problem has been corrected.
b.
If foam is not delivered, notify Supervisor.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION