TM 9-2320-328-13&P-1
0048-6
DRAFT
0048
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT1893AA
NOTE
Hydraulic reservoir oil level must be checked with vehicle parked on level ground.
Step 4.
Open pump house panel K access door (WP 0008).
Check hydraulic reservoir oil level
at normal operating temperature.
If hydraulic reservoir oil level is low, fill to proper level (WP 0145).
HWT1894
Step 5.
Check hydraulic heat exchanger for blockage.
a.
If hydraulic heat exchanger is blocked, remove blockage.
b.
If hydraulic heat exchanger is not blocked, notify Supervisor.