TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 334 of 1318

TM 9-2320-328-13&P-1
0049-2
DRAFT
0049
Change 1
..
Step 3.
If operating pressure governor control from pump operator’s panel, check if cab
pressure governor control is active (WP 0017).
..
If active, disable cab pressure governor control (WP 0017).
..
HWT1083
..
Step 4.
Check if pressure governor control displays Pump Engaged (WP 0017).
..
If PUMP ENGAGED indicator is not displayed, go to Step 6.
..
HWT1335
..
Step 5.
If operating from cab, check if pressure governor control displays Ok to Pump or Ok to
Pump and Roll (WP 0017).
..
a.
If Ok to Pump or Ok to Pump and Roll is not displayed, go to Step 8.
..
b.
If Ok to Pump or Ok to Pump and Roll is displayed, notify Supervisor.
..
..
..
..
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top