TM 9-2320-328-13&P-1
0063-24
DRAFT
0063
HWT2073
WARNING
ICON 26,66
•
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
•
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air line at bumper turret pattern sleeve and
observing air pressure escaping from air line, when bumper turret control is activated.
Step 33.
Install bumper turret control cover and tighten four screws. Disconnect air line at
bumper turret pattern sleeve retract port. Do not remove adjustment valve from sleeve.
While an assistant pushes bumper turret control pattern control switch to fog position
(WP 0004), check if air pressure is present at bumper turret pattern sleeve retract port.
Connect air line at bumper turret pattern sleeve retract port.
If air pressure is present, go to Step 38.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION