TM 9-2320-328-13&P-1
0063-14
DRAFT
0063
HWT672
WARNING
ICON 26,66
•
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
•
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air lines at bumper turret junction box and
observing air pressure escaping from air line.
System air pressure may drop below 85 psi
(586 kPa) during this procedure.
Step 15.
Release bumper turret control discharge switch (WP 0004).
Remove bumper turret
cover (WP 0376).
Disconnect air line at bumper turret junction box.
Check if air
pressure is present at bumper turret junction box.
If there is no air pressure, replace air line to bumper turret junction
box (WP 0374).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION