TM 9-2320-328-13&P-1
0063-10
DRAFT
0063
HWT0673
Step 11.
Install circuit breaker FS 1 (WP 0242).
Disconnect cab instrument panel wire harness
cab power distribution wire harness connector.
With a test lead set, check for continuity
across cab instrument panel wire harness wire 2848 (red) from cab instrument panel
wire harness cab power distribution wire harness connector, terminal 1 to bumper turret
control connector, terminal 1.
a.
If there is continuity, repair wire 2848 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
b.
If there is no continuity, repair wire 2848 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0279).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top