TM 9-2320-328-13&P-1
0063-2
DRAFT
0063
HWT0395
NOTE
•
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves and operate bumper turret.
•
Do not engage PUMP PTO during this procedure, except when performing complete
system checks.
Valve operations can be checked without water pump operation.
•
Valve operations can be checked by observing valve shaft rotation. Valves are open when
tabs or yellow paint tabs are aligned with fluid flow.
Step 1.
If system air pressure is below 85 psi (586 kPa), start engine and allow system air
pressure to build to at least 85 psi (586 kPa) (TM 9-2320-422-10).
Then shut off
engine (TM 9-2320-422-10).
Remove pump house panel H (WP 0339).
Push battery
disconnect switch to on position (WP 0007).
Put bumper turret control POWER switch
to
|
(on) position (WP 0004).
While an assistant pushes and holds bumper turret control
discharge switch (WP 0004), check if bumper turret valve operates to open position.
If bumper turret valve operates to open position, go to Step 15.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION