CAUTION
Both connector ends of foam level probe adapter must be covered with heat
shrink tubing.
Failure to comply will allow moisture to enter connector ends and
not allow foam level gauge to function properly.
..
Step 21.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across wire 2740 (black) from passenger side body wire harness foam level
probe connector, terminal A to a known good ground.
..
If there is continuity, go to Step 14.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION