TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 79 of 1318

TM 9-2320-328-13&P-1
0004-17
DRAFT
0004
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT0195
Figure 15. Driver Side - Pump House (Sheet 2 of 2).
Key
Fig. 15
Control or Indicator
Function
10
NO. 1 DRIVER SIDE
DISCHARGE
Discharge connection for use with 3 in. (7.6 cm) soft discharge
hose.
11
DRIVER SIDE AUX. INLET
Used to pump water from hydrant or positive water source.
12
Driver Side Main Inlet
Used to pump water from pond or draft.
13
Main Inlet Strainer
Used to keep debris from entering main inlet.
14
DRIVER SIDE AUX. INLET
Strainer
Used to keep debris from entering DRIVER SIDE AUX. INLET.
15
AUTO/MANUAL SELECTOR
VALVE
Used to put hydraulic controls in manual operation mode.


Back to Top