TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 985 of 1318

TM 9-2320-328-13&P-1
0088-3
DRAFT
0088
HWT0702
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 2.
Put pump operator’s panel DIRECT TANK FILL switch to OFF position (WP 0004).
Pull
battery disconnect switch to off position (WP 0007).
Remove lamp from pump
operator’s panel DIRECT TANK FILL open indicator (WP 0214).
Check for continuity
across lamp.
If there is no continuity, replace DIRECT TANK FILL open indicator lamp
(WP 0214).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top