TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 147 of 844

TM 9-2320-328-13&P-3
0342-9
DRAFT
0342
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
27. Remove four locknuts (67), screws (68), and two rubber latches (69) from pump operator’s panel
housing (30).
Discard locknuts.
END OF TASK
INSTALLATION
1.
Install two rubber latches (69) on pump operator’s panel housing (30) with four screws (68) and locknuts (67).
2.
Install access trim plate (66) on pump operator’s panel housing (30) with four washers (65), lockwashers (64),
and screws (63).
3.
Install terminal block (39) on pump operator’s panel housing (30) with two screws (62) and locknuts (61).
4.
With the aid of an assistant, install pump operator’s panel housing (30) on vehicle with seven washers (60),
lockwashers (59), and screws (58).
HWT3037


Back to Top